Pavel Osmančík

ORCID: 0000-0003-0482-4448
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Cardiac Arrhythmias and Treatments
  • Atrial Fibrillation Management and Outcomes
  • Cardiac pacing and defibrillation studies
  • Cardiac electrophysiology and arrhythmias
  • Antiplatelet Therapy and Cardiovascular Diseases
  • Cardiac and Coronary Surgery Techniques
  • Cardiac Imaging and Diagnostics
  • Acute Myocardial Infarction Research
  • Cardiac, Anesthesia and Surgical Outcomes
  • Cardiac Structural Anomalies and Repair
  • Heart Rate Variability and Autonomic Control
  • Neurological disorders and treatments
  • Venous Thromboembolism Diagnosis and Management
  • Heart Failure Treatment and Management
  • Coronary Interventions and Diagnostics
  • Cardiovascular Function and Risk Factors
  • Cardiovascular Syncope and Autonomic Disorders
  • ECG Monitoring and Analysis
  • Cardiac Valve Diseases and Treatments
  • Diabetes Treatment and Management
  • Inflammatory mediators and NSAID effects
  • Cardiac Fibrosis and Remodeling
  • Cardiac tumors and thrombi
  • Cardiovascular Disease and Adiposity
  • Infective Endocarditis Diagnosis and Management

Charles University
2016-2025

University Hospital Kralovske Vinohrady
2016-2025

Palacký University Olomouc
2024

Czech Academy of Sciences, Institute of Scientific Instruments
2020

Ocní klinika
2010-2016

Janssen (United States)
2016

In-Q-Tel
2009

Prague University of Economics and Business
2004

Leipzig University
2002

University Hospital Leipzig
2001

Nonselective His-bundle pacing (nsHBp), nonselective left bundle branch (nsLBBp), and ventricular septal myocardial (LVSP) are recognized as physiological techniques.The purpose of this study was to compare differences in depolarization between these techniques using ultra-high-frequency electrocardiography (UHF-ECG).In patients with bradycardia, nsHBp, nsLBBp (confirmed concomitant [LBB] capture), LVSP (pacing [LV] position without proven LBB capture) were performed. Timings activations...

10.1016/j.hrthm.2021.04.025 article EN cc-by-nc-nd Heart Rhythm 2021-04-28
Emmanuel Ekanem Petr Neužil Tobias Reichlin J Kautzner Pepijn van der Voort and 95 more Pierre Jaı̈s Gian‐Battista Chierchia Alan Bulava Yuri Blaauw Tomáš Skála Martin Fiala Mattias Duytschaever Gábor Széplaki Boris Schmidt Grégoire Massoullié Kars Neven Olivier Thomas Johan Vijgen Estelle Gandjbakhch Douglas S. Scherr Arne Johannessen David Keane Serge Bovéda Philippe Maury Ignacio García-Bolao Ante Anić Peter S. Hansen Franck Raczka Antoine Lepillier Yves Guyomar Dhiraj Gupta Jurren M. van Opstal Pascal Defaye Christian Sticherling Philipp Sommer Pavel Kučera Joaquín Osca Fariborz Tabrizi Antoine Roux Michael W. Gramlich Stefano Bianchi Pedro Adragão Francesco Solimene Claudio Tondo Antonio Dello Russo Jürgen Schreieck Armin Luik Obaida R. Rana Gerrit Frommeyer Frédéric Anselme Ingo Kreis Raphaël Rosso Andreas Metzner László Gellér Samuel H. Baldinger Ángel Ferrero Stephan Willems Andreas Goette Greg Mellor Shibu Mathew Łukasz Szumowski Roland Richard Tilz Saverio Iacopino Peter Karl Jacobsen Antony George Pavel Osmančík Stefan G. Spitzer Richard Balasubramaniam Abdul Shokor Parwani Thomas Deneke Andrzej Główniak Antonio Rossillo Helmut Pürerfellner David Duncker P Reil Thomas Arentz Daniel Steven Juan J. Olalla Jonas S.S.G. de Jong Reza Wakili Sélim Abbey Gottschling Timo Antonio Asso Tom Wong Bertrand Pierre Niels Christian Ewertsen Leonard Bergau Cristina Lozano-Granero Maximo Rivero Alexander Breitenstein J Inkovaara Samir Fareh Decebal Gabriel Lațcu Dominik Linz Patrick Müller Javier Ramos‐Maqueda Thomas Beiert Sakis Themistoclakis Dirk Große Meininghaus G Stix

Abstract Pulsed field ablation (PFA) is an emerging technology for the treatment of atrial fibrillation (AF), which pre-clinical and early-stage clinical data are suggestive some degree preferentiality to myocardial tissue without damage adjacent structures. Here in MANIFEST-17K study we assessed safety PFA by studying post-approval use this modality. Of 116 centers performing with a pentaspline catheter, were received from 106 (91.4% participation) regarding 17,642 patients undergoing (mean...

10.1038/s41591-024-03114-3 article EN cc-by Nature Medicine 2024-07-01

Hemolysis-related renal failure has been described after pulmonary vein isolation (PVI) with pulsed field ablation (PFA). To compare the potential for hemolysis during PVI PFA versus radiofrequency (RFA). In consecutive patients, was performed or RFA. Blood samples were drawn at baseline, immediately post-ablation, and 24 hours post-ablation. Using flow cytometry, concentration of red blood cell microparticles (RBCμ, fragments damaged erythrocytes) in also assessed. Lactate-dehydrogenase...

10.1016/j.jacep.2024.05.001 article EN cc-by JACC. Clinical electrophysiology 2024-05-16

Abstract A significant proportion of patients who suffer from atrial fibrillation and are in need thromboembolic protection not treated with oral anticoagulation or discontinue this treatment shortly after its initiation. This undertreatment has improved sufficiently despite the availability direct anticoagulants which associated less major bleeding than vitamin K antagonists. Multiple reasons account for this, including events ischaemic strokes whilst on anticoagulation, a serious risk...

10.1093/europace/euae035 article EN cc-by EP Europace 2024-01-29

AimsSurgical ablation procedure can restore sinus rhythm (SR) in patients with atrial fibrillation (AF) undergoing cardiac surgery. However, it is not known whether has any impact on long-term clinical outcomes.

10.1093/eurheartj/ehs290 article EN cc-by-nc European Heart Journal 2012-08-28

Left bundle branch pacing (LBBP) produces delayed, unphysiological activation of the right ventricle. Using ultra-high-frequency electrocardiography (UHF-ECG), we explored how bipolar anodal septal with direct LBB capture (aLBBP) affects resultant ventricular depolarization pattern.In patients bradycardia, His (HBP), unipolar nonselective LBBP (nsLBBP), aLBBP, and (RVSP) were performed. Timing local activation, in leads V1-V8, was displayed using UHF-ECG, electrical dyssynchrony (e-DYS)...

10.3389/fcvm.2023.1140988 article EN cc-by Frontiers in Cardiovascular Medicine 2023-03-22

Pulsed-field ablation (PFA) represents a new, non-thermal energy for the of AF. Ablation energies producing thermal injury are associated with an inflammatory response, platelet, and coagulation activation. The study aimed to compare systemic response in patients undergoing PVI using PF radiofrequency (RF) energy. Patients AF indicated were enrolled randomly assigned undergo RF (CARTO Smart Touch, Biosense Webster) or (Farapulse, Boston-Scientific) Markers myocardial damage (troponin I),...

10.1016/j.jacep.2023.11.001 article EN cc-by JACC. Clinical electrophysiology 2023-11-06

Biventricular pacing (Biv) and left bundle branch area (LBBAP) are methods of cardiac resynchronization therapy (CRT). Currently, little is known about how they differ in terms ventricular activation. This study compared activation patterns block (LBBB) heart failure patients using an ultra-high-frequency electrocardiography (UHF-ECG). was a retrospective analysis including 80 CRT from two centres. UHF-ECG data were obtained during LBBB, LBBAP, Biv. Left divided into non-selective (NSLBBP)...

10.1093/eurheartjsupp/suad109 article EN cc-by-nc European Heart Journal Supplements 2023-03-22

Abstract Aims Data on the hybrid atrial fibrillation (AF) treatment are lacking in patients with structural heart disease undergoing concomitant CryoMaze procedures. The aim was to assess whether timely pre-emptive catheter ablation would achieve higher freedom from AF or tachycardia (AT) and be associated better clinical outcomes than surgical alone. Methods results trial investigated non-paroxysmal coronary artery bypass grafting and/or valve repair/replacement mandatory procedure who were...

10.1093/europace/euae040 article EN cc-by EP Europace 2024-02-01

The aim of the study was to verify correct anchoring location for tip right ventricular lead using cardiac computed tomography and assess best fluoroscopic ECG criteria associated with electrode into midseptum.Patients indicated pacemaker implantation were prospectively enrolled. implanted midseptum according standard in left anterior oblique 40 view. shadow on 30 divided 4 quadrants perpendicular lateral silhouette position analyzed. exact assessed tomography. Of 51 patients, anchored 21...

10.1161/circep.113.000232 article EN Circulation Arrhythmia and Electrophysiology 2013-06-07

The present study introduces a new ultra-high-frequency 14-lead electrocardiogram technique (UHF-ECG) for mapping ventricular depolarization patterns and calculation of novel dyssynchrony parameters that may improve the selection patients application cardiac resynchronization therapy (CRT).Components ECG in sixteen frequency bands within 150 to 1000 Hz range were used create maps. maximum time difference between UHF QRS complex centers mass leads V1 V8 was defined as electrical (e-DYS),...

10.1111/jce.14299 article EN Journal of Cardiovascular Electrophysiology 2019-12-02

Background: Three different ventricular capture types are observed during left bundle branch pacing (LBBp). They selective LBB (sLBBp), non-selective (nsLBBp), and myocardial septal transiting from nsLBBp while decreasing the output (LVSP). Study aimed to compare differences in depolarization between these captures using ultra-high-frequency electrocardiography (UHF-ECG). Methods: Using decremental voltage output, we identified studied nsLBBp, sLBBp, LVSP patients with bradycardia. Timing of...

10.3389/fcvm.2021.787414 article EN cc-by Frontiers in Cardiovascular Medicine 2021-12-07

Abstract Background Right ventricular (RV) pacing causes delayed activation of remote segments. We used the ultra‐high‐frequency ECG (UHF‐ECG) to describe depolarization when different RV locations. Methods In 51 patients, temporary was performed at septum (mSp); further subclassified as right inflow tract (RVIT) and outflow (RVOT) for septal positions (below or above plane His bundle in anterior oblique), apex, lateral wall, basal with nonselective RBB capture (nsHBorRBBp). The timings...

10.1111/jce.14985 article EN Journal of Cardiovascular Electrophysiology 2021-03-08

The effect of left ventricular myocardial septal (LVSP) and bundle branch pacing (LBBP) on synchrony LV hemodynamics is poorly understood. To investigate the impact LVSP LBBP versus biventricular (BVP) electrical in CRT patients. In candidates with conduction disease, was assessed by measuring QRSd using ultra-high-frequency ECG (UHF-ECG). (lv-DYS) as a difference between first activation V1-V8 to last from V4-V8. estimated invasive systolic blood pressure measurement during multiple...

10.1016/j.jacep.2024.04.022 article EN cc-by JACC. Clinical electrophysiology 2024-05-16

Electrical cardioversion presents one of the treatment options for atrial fibrillation (AF). However, early recurrence rate is high, reaching ~40% three months after procedure. Features based on vectorcardiographic signals were explored to find association with AF. Eighty-four patients non-paroxysmal AF referred electrical prospectively studied; was present in 40 (47.6%). Patients underwent 24-h Holter ECG monitoring procedure assess recurrence. Pre-procedural 12-lead ECGs (10 s, 1 kHz)...

10.1038/s41598-025-85340-4 article EN cc-by-nc-nd Scientific Reports 2025-01-08

10.1016/s0735-1097(25)00646-1 article EN Journal of the American College of Cardiology 2025-03-29
Coming Soon ...