Antonio Sorgente

ORCID: 0000-0002-0078-9393
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Cardiac Arrhythmias and Treatments
  • Atrial Fibrillation Management and Outcomes
  • Cardiac electrophysiology and arrhythmias
  • Cardiac pacing and defibrillation studies
  • ECG Monitoring and Analysis
  • Ion channel regulation and function
  • Cardiovascular Syncope and Autonomic Disorders
  • Cardiac Imaging and Diagnostics
  • Cardiomyopathy and Myosin Studies
  • Cardiovascular Effects of Exercise
  • Cardiovascular Function and Risk Factors
  • Heart Failure Treatment and Management
  • Cardiac Structural Anomalies and Repair
  • COVID-19 Clinical Research Studies
  • Cerebrovascular and Carotid Artery Diseases
  • Cardiac Valve Diseases and Treatments
  • Venous Thromboembolism Diagnosis and Management
  • Cardiac Arrest and Resuscitation
  • Cardiovascular and Diving-Related Complications
  • Respiratory Support and Mechanisms
  • Pericarditis and Cardiac Tamponade
  • Receptor Mechanisms and Signaling
  • Long-Term Effects of COVID-19
  • Botulinum Toxin and Related Neurological Disorders
  • Neuroscience and Neural Engineering

Universitair Ziekenhuis Brussel
2009-2025

Vrije Universiteit Brussel
2010-2025

Centre Hospitalier de Mouscron
2021-2024

Epicura
2020-2023

Ingegneria dei Sistemi (Italy)
2023

Intel (United States)
2023

Fundación Juan March
2010-2023

Maria Cecilia Hospital
2023

Institute of Applied Science and Intelligent Systems
2022

Cleveland Clinic
2015-2021

With the increasing interest in conduction system pacing (CSP) over last few years and inclusion of this treatment modality current guidelines, our aim was to provide a snapshot practice across Europe. An online questionnaire sent physicians participating European Heart Rhythm Association research network as well national societies social media. Data on previous experience with CSP, indications, preferred tools, unmet needs, perceptions for future are reported discussed.

10.1093/europace/euac201 article EN EP Europace 2022-11-22

Abstract Aims Pulsed field ablation (PFA) has emerged as a novel, non-thermal energy source to selectively ablate cardiac tissue. We describe multicentre experience on pulmonary vein isolation (PVI) via the pentaspline Farapulse™ PFA system vs. thermal-based technologies in propensity score-matched population of paroxysmal atrial fibrillation (PAF) patients. Methods and results Propensity score matching was adopted compare PVI-only outcomes Farawave™ (Group PFA), cryoballoon CRYO), or focal...

10.1093/europace/euae016 article EN cc-by EP Europace 2023-12-28

Abstract Aims The multielectrode radiofrequency balloon catheter (RFB) has been developed to achieve safe and effective pulmonary vein isolation (PVI) for atrial fibrillation (AF) ablation. This single-centre study aimed evaluate the midterm clinical outcome predictors of single-shot PVI with novel RFB. Methods results All consecutive patients symptomatic paroxysmal or persistent AF undergoing first-time RFB were prospectively included. Clinical procedural parameters systematically...

10.1093/europace/euad017 article EN cc-by-nc EP Europace 2023-02-04

A pathogenic/likely pathogenic variant can be found in 20% to 25% of patients with Brugada syndrome (BrS) and a SCN5A is associated worse prognosis. The aim this study define the diagnostic yield large gene panel American College Medical Genetics Genomics classification assess prognosis non-SCN5A variants.

10.1161/circep.123.012374 article EN Circulation Arrhythmia and Electrophysiology 2024-03-01

Functional mitral regurgitation (MR) could be managed by both cardiac resynchronization therapy (CRT) and mitral-valve surgery. Clinical decision making regarding the appropriateness of surgery vs. CRT is a challenging task. This study assessed prevalence prognosis various degrees functional MR in candidates. Additionally, we sought to identify patients who either can adequately only or will need Cardiac recipients (n= 794) were followed-up for 26 ± 18 months. Mitral severity was quantified...

10.1093/europace/eur047 article EN EP Europace 2011-04-12

AimsNo specific data are available on the influence of pulmonary vein (PV) anatomy and shape cryoballoon ablation (CA) catheter efficacy in delivering cryothermal energy and, consequently, obtaining PV isolation.

10.1093/europace/euq388 article EN other-oa EP Europace 2010-10-25

We sought to investigate the value of a family history sudden death (SD) in Brugada syndrome (BS). Two hundred and eighty consecutive patients (mean age: 41 ± 18 years, 168 males) with diagnostic type I ECG pattern were included. Sudden occurred 69 (43%) 157 families. One ten SDs analysed. During follow-up VF (ventricular fibrillation) or SD-free survival rate was not different between without SD first-degree relative, multiple relative at any age relatives ≤35 years. patient had two years...

10.1093/eurheartj/ehr129 article EN European Heart Journal 2011-07-04

Abstract Background and Aims Pulmonary vein isolation (PVI) is the most effective rhythm control strategy in paroxysmal atrial fibrillation (AF). Pulsed field ablation (PFA) has emerged as a novel, non-thermal energy source to selectively ablate cardiac tissue. We report first multicenter experience on PVI via pentaspline FarapulseTM PFA system versus thermal-based technologies propensity score-matched population of AF patients. Methods Propensity score matching was adopted compare PVI-only...

10.1093/europace/euae102.175 article EN cc-by-nc EP Europace 2024-05-01

Objectives: Assess the predictive accuracy of WHO COVID-19 severity classification on hospitalized patients. The secondary aim was to compare its power with a new prediction model, named EPI-SCORE, based Bayesian network analysis. Methods: We retrospectively analyzed population 295 RT-PCR positive patients at Epicura Hospital Center, Belgium, admitted between March 1st and April 30th, 2020. Results: Our cohort’s median age 73 (62–83) years, female proportion 43%. All were classified...

10.3390/pathogens9110880 article EN cc-by Pathogens 2020-10-24

Hybrid atrial fibrillation (AF) ablation is a promising approach in non-paroxysmal AF. The aim of this study to assess the long-term outcomes hybrid large cohort patients after both an initial and as redo procedure.All consecutive undergoing AF at UZ Brussel from 2010 2020 were retrospectively evaluated. was performed one-step procedure: (i) thoracoscopic followed by (ii) endocardial mapping eventual ablation. All received PVI posterior wall isolation. Additional lesions based on clinical...

10.1093/europace/euad114 article EN cc-by-nc EP Europace 2023-05-01

BACKGROUND: Pulsed field ablation (PFA) is a novel technology for catheter-based atrial arrhythmia treatment. Evidence of its application ventricular still limited. In this study, we describe the feasibility and efficacy focal PFA premature contraction (PVC) ablation. METHODS: A prospective cohort 20 patients referred PVC at 2 centers was enrolled, regardless presence structural heart disease, morphology, or previous attempts. All procedures were performed using CENTAURI System in...

10.1161/circep.124.012826 article EN other-oa Circulation Arrhythmia and Electrophysiology 2024-09-01

Atrial fibrillation (AF) ablation is increasingly being performed in electrophysiology laboratories. Pericardial effusion (PE) certainly one of the most frequently observed complications during AF ablation. The aim our study was to investigate incidence and outcome PE following cryothermal energy balloon (CBA) comparison with conventional circumferential pulmonary vein isolation a focal radiofrequency (RF) catheter.A total 133 consecutive patients (105 males) paroxysmal were included this...

10.1093/europace/eup422 article EN EP Europace 2010-01-06

Abstract Conventional stylet‐driven leads with extendable helix can be implanted successfully for left bundle branch area pacing (LBBAP) a low acute complication rate. We report two cases in which lead repositioning after first unsuccessful attempt to LBBAP was associated fracture of the rotating mechanism and failure fully extract lead.

10.1111/jce.15030 article EN Journal of Cardiovascular Electrophysiology 2021-04-07

Abstract Introduction Pulmonary vein isolation (PVI) with thermal energy is characterized by concomitant ablation of the surrounding ganglionated plexi (GP). Pulsed‐field (PFA) selectively targets myocardium and seems associated only negligible effects on autonomic nervous system (ANS). However, little known about dynamic PFA GP immediately after PVI. This study sought to investigate degree acute vagal modulation induced Farapulse TM during PVI compared single‐shot ablation. Methods A total...

10.1111/jce.16089 article EN Journal of Cardiovascular Electrophysiology 2023-10-04

Cryoballoon (CB) ablation is the mainstay of single-shot pulmonary vein isolation (PVI). A radiofrequency balloon (RFB) catheter has recently emerged as an alternative. However, these two technologies have not been compared. This study aims to evaluate freedom from atrial tachyarrhythmias (ATas) at 1 year: procedural characteristics, efficacy, and safety novel RFB compared with CB for PVI in patients paroxysmal fibrillation (AF).This prospective multi-centre included consecutive symptomatic...

10.1093/europace/euad252 article EN cc-by-nc EP Europace 2023-08-02

Abstract Aims Atrial fibrillation (AF) and chronic kidney disease (CKD) often coexist share an increased risk of thrombo-embolism (TE). CKD concomitantly predisposes towards a pro-haemorrhagic state. Our aim was to evaluate the prognostic value in patients undergoing percutaneous left atrial appendage occlusion (LAAO). Methods results A total 2124 consecutive AF LAAO were categorized into stage 1+2 (n = 1089), 3 796), 4 170), 5 69) based on estimated glomerular filtration rate at baseline....

10.1093/europace/euad315 article EN cc-by EP Europace 2023-10-27
Coming Soon ...