E. Hazen

ORCID: 0009-0005-6058-4129
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Particle physics theoretical and experimental studies
  • Particle Detector Development and Performance
  • High-Energy Particle Collisions Research
  • Dark Matter and Cosmic Phenomena
  • Radiation Detection and Scintillator Technologies
  • Distributed and Parallel Computing Systems
  • Astrophysics and Cosmic Phenomena
  • Quantum Chromodynamics and Particle Interactions
  • Neutrino Physics Research
  • Computational Physics and Python Applications
  • Stroke Rehabilitation and Recovery
  • Acute Ischemic Stroke Management
  • Balance, Gait, and Falls Prevention
  • Superconducting Materials and Applications
  • Cardiovascular Health and Disease Prevention
  • Peripheral Artery Disease Management
  • Atomic and Subatomic Physics Research
  • Particle Accelerators and Free-Electron Lasers
  • CCD and CMOS Imaging Sensors
  • Neuroendocrine regulation and behavior
  • Neurological Disorders and Treatments
  • Radiation Effects in Electronics
  • Medical Imaging Techniques and Applications
  • Travel-related health issues
  • Human-Animal Interaction Studies

University of Kansas Medical Center
2023-2024

University Medical Center
2024

University Hospital and Clinics
2024

Boston University
1988-2022

Colgate University
2022

The University of Texas at Austin
2020

European Organization for Nuclear Research
1996

University of Washington
1991

Kobe University
1991

Tohoku University
1991

The Apollo Advanced Telecommunications Computing Architecture (ATCA) platform is an open-source design consisting of a generic "Service Module" (SM) and customizable "Command (CM), allowing for cost-effective use in applications such as the readout inner tracker Level-1 track trigger CMS Phase-II upgrade at HL-LHC. SM integrates intelligent IPMC, robust power entry conditioning systems, powerful system-on-module computer, flexible clock communication infrastructure. CM designed around two...

10.48550/arxiv.2501.03702 preprint EN arXiv (Cornell University) 2025-01-07

The anomalous magnetic moment of the muon is one most precisely measured quantities in experimental particle physics. Its latest measurement at Brookhaven National Laboratory deviates from Standard Model expectation by approximately 3.5 standard deviations. goal new experiment, E989, now under construction Fermilab, a fourfold improvement precision. Here, we discuss details future and its current status.

10.1063/1.4917553 article EN Journal of Physical and Chemical Reference Data 2015-06-17

We discuss the preparation of different samples CR39 polymer and a number tests performed with high energy heavy ions. The quality reproducibility manufactured is discussed as well implications for large area detector (MACRO) used search cosmic magnetic monopoles.

10.1016/1359-0189(91)90284-o article EN cc-by-nc-nd International Journal of Radiation Applications and Instrumentation Part D Nuclear Tracks and Radiation Measurements 1991-01-01

10.1016/0168-9002(88)90885-6 article EN Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment 1988-06-01

We are developing a Micro TCA Carrier Hub card which provides timing, control and data acquisition functions in crate for HL-LHC readout electronics. This module may be mounted the primary or redundant MCH slot crate, distributes low-jitter LHC RF clock encoded fast timing signals to up 12 AMC modules. In addition, it receives buffer status DAQ at 600 MBytes/sec from each AMC. The prototype is built on commercial base board with custom mezzanine stack. latest Xilinx® Virtex®-6 FPGA used...

10.1088/1748-0221/5/12/c12042 article EN Journal of Instrumentation 2010-12-20

The challenging conditions of the High-Luminosity LHC require tailored hardware designs for trigger and data acquisition systems. Apollo platform features a "Service Module" with powerful system-on-module computer that provides standard ATCA communications application-specific "Command Module"s large FPGAs high-speed optical fiber links. CMS version will be used track finder pixel readout. It up to two more than 100 links speeds 25\,Gb/s. We study carefully design performance board by using...

10.1088/1748-0221/17/04/c04033 article EN cc-by Journal of Instrumentation 2022-04-01

Background Navigating the complexities of post-stroke recovery trials requires addressing challenges in participant recruitment and retention effective resource management to ensure trial success. The aim this study was examine financial requirements associated with conducting Moderate-Intensity Exercise vs. High-Intensity Interval Training Recover Walking Post-Stroke (HIT Stroke Trial) at a single site encompassing wide catchment area, recognizing intricate inherent trials. Methods To...

10.3389/fstro.2024.1425385 article EN cc-by Frontiers in Stroke 2024-09-23

Abstract Background Control of breathing is known to be adversely affected by cognitive impairment, often associated with sleep apnea or disordered during in MCI/AD. The origin this disorder thought the dysfunction respiratory control centers brainstem impaired afferent signaling from cortical regions. Continuous data were collected a multi‐center study Los Angeles (USC), Kansas City (KUMC) and Dallas (UT‐SWMC), used compute rate variability (RRV) test hypothesis that voluntary MCI mild AD...

10.1002/alz.092034 article EN cc-by Alzheimer s & Dementia 2024-12-01

Abstract Background A multi‐center study in Los Angeles (USC), Kansas City (KUMC) and Dallas (UT‐SWMC) quantified via predictive modeling the dynamics of cerebral perfusion regulation (CO2 vasoreactivity autoregulation) MCI/AD patients cognitively normal controls under resting conditions. The goal was to develop model‐based physio‐markers for accurate diagnosis MCI pre‐clinical AD, motivated by our previous findings significant impairment mild AD patients. Method Continuous spontaneous...

10.1002/alz.091661 article EN cc-by Alzheimer s & Dementia 2024-12-01

Abstract BACKGROUND Age-related decline in cerebrovascular health precipitates cognitive dysfunction and can be attenuated by habitual physical activity. Cognitive interference balance control is well-known clinically reflects compromised neuromotor resilience. However, whether affects cognitive-balance dual-tasking with aging unclear. METHODS Thirty participants (76±4years) completed clinical balance/cognitive testing under single-task dual-task conditions. Balance performance was assessed...

10.1101/2023.12.19.572430 preprint EN cc-by-nc bioRxiv (Cold Spring Harbor Laboratory) 2023-12-20

Abstract Background Post-stroke recovery trials pose distinct recruitment and retention challenges, understanding the financial requirements of conducting randomized controlled is crucial to ensure sufficient resources for successful study execution. The purpose this analysis was quantify costs at a single site with large catchment area Moderate-Intensity Exercise Versus High-Intensity Interval Training Recover Walking Post-Stroke, HIT Stroke Trial. Methods To determine cost, expense reports...

10.1101/2023.12.20.23300342 preprint EN cc-by-nc-nd medRxiv (Cold Spring Harbor Laboratory) 2023-12-24

Introduction: Bird fancier’s lung is a form of hypersensitivity pneumonitis caused by non-atopic immunologic response to the inhalation avian antigens. Although it most common type in adults, rarely diagnosed pediatric population. Case Report: A 17-year-old male with intermittent asthma presented chronic cough, progressively worsening shortness breath, joint pain and swelling his wrists knees, night sweats. Eight months prior presentation he had been pneumonia lost 24 pounds since that time....

10.1542/peds.146.1_meetingabstract.447 article EN PEDIATRICS 2020-07-01

The ATLAS MDT Muon Spectrometer is a system of approximately 380,000 pressurized cylindrical drift tubes 3 cm diameter and up to 6 meters in length. These Monitored Drift Tubes (MDTs) are precision-glued form super-layers, which turn assembled into precision chambers 432 each. Each chamber equipped with set mezzanine cards containing analog digital readout circuitry sufficient read out 24 MDTs per card. Up 18 these connected an on-chamber DAQ element referred as Chamber Service Module, or...

10.1109/nssmic.2003.1352082 article EN 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515) 2003-01-01
Coming Soon ...