- Advanced MEMS and NEMS Technologies
- Mechanical and Optical Resonators
- Intensive Care Unit Cognitive Disorders
- Force Microscopy Techniques and Applications
- Gastric Cancer Management and Outcomes
- Graphene research and applications
- Acoustic Wave Resonator Technologies
- Cardiac Imaging and Diagnostics
- Helicobacter pylori-related gastroenterology studies
- Cardiac Ischemia and Reperfusion
- Acute Myocardial Infarction Research
- Advanced Sensor and Energy Harvesting Materials
- Heart Failure Treatment and Management
- Ferroelectric and Piezoelectric Materials
- Family and Patient Care in Intensive Care Units
- Photonic and Optical Devices
- Coronary Interventions and Diagnostics
- Peripheral Artery Disease Management
- Diabetes Treatment and Management
- Respiratory Support and Mechanisms
- Nosocomial Infections in ICU
- Antiplatelet Therapy and Cardiovascular Diseases
- Carbon Nanotubes in Composites
- Millimeter-Wave Propagation and Modeling
- Diamond and Carbon-based Materials Research
Fujita Health University Hospital
2018-2025
Toranomon Hospital
2023-2024
Okayama Prefecture
2017-2024
Tokyo Medical University
2021-2024
Mirion Technologies (France)
2024
Setsunan University
2023
Tokyo Medical and Dental University Hospital
2023
Japanese Red Cross Kyushu International College of Nursing
2023
Sapporo City University
2023
Saitama Red Cross Hospital
2023
A label-free biological sensor, which is based on the resonant transmission phenomenon of a thin metallic mesh, proposed in terahertz wave region. By using this we demonstrate highly sensitive detection small amounts protein horseradish peroxidase. For quantitative investigation sensitivity our peroxidase was printed mesh surface by commercial available printer. distinct shift dip frequency observed for 500pg∕mm2 (11fmol) indicating significantly high sensor.
The Japanese Clinical Practice Guidelines for Management of Sepsis and Septic Shock 2020 (J-SSCG 2020), a Japanese-specific set clinical practice guidelines sepsis septic shock created as revised from J-SSCG 2016 jointly by the Society Intensive Care Medicine Association Acute Medicine, was first released in September published February 2021. An English-language version these based on contents original Japanese-language version. purpose this guideline is to assist medical staff making...
This paper reports solutions to the issues of profile control, microloading effect and suppression sidewall roughness submicrometer trenches by modifying regular conditions Bosch process that is often employed in inductively coupled plasma (ICP) deep reactive ion etching (DRIE) system. Additionally, under modified processing conditions, a high efficient antireflection structure can be fabricated.
Background Effects of sodium‐glucose cotransporter 2 inhibitors on reducing hospitalization for heart failure have been reported in randomized controlled trials, but their effects patients with preserved ejection fraction ( HF p EF ) are unknown. This study aimed to evaluate the drug efficacy luseogliflozin, a inhibitor, type diabetes mellitus and . Methods Results We performed multicenter, open‐label, randomized, trial comparing luseogliflozin 2.5 mg once daily voglibose 0.2 3 times...
We herein report a case of Systemic Capillary Leak Syndrome (SCLS) attributed to coronavirus disease (COVID-19) that emerged in 2019. A 56-year-old woman presented with COVID-19 infection 7 days prior the visit upper respiratory symptoms, fatigue, and decreased appetite. Secondary SCLS due was diagnosed, veno-arterial extracorporeal membrane oxygenation (VA-ECMO) initiated as mechanical support, intravenous immunoglobulin administered, marking transition recovery phase initiation fluid...
Abstract The 2024 revised edition of the Japanese Clinical Practice Guidelines for Management Sepsis and Septic Shock (J‐SSCG 2024) is published by Society Intensive Care Medicine Association Acute Medicine. This fourth revision since first was in 2012. purpose guidelines to assist healthcare providers making appropriate decisions treatment sepsis septic shock, leading improved patient outcomes. We aimed create that are easy understand use physicians who recognize provide initial management,...
A new image-enhanced endoscopy method called texture and colour enhancement imaging (TXI) enhances brightness, surface irregularities, subtle changes in endoscopic images. However, it is unclear whether TXI narrow-band (NBI) with third-generation high-vision transnasal ultrathin are advantageous over white-light (WLI) for detecting atrophy, intestinal metaplasia, map-like redness gastric cancer. We investigated to compare the efficacy evaluation of gastritis between NBI clarified compared...
Epitaxial graphene (EG) on SiC is promising owing to a capability produce high-quality film wafer scale. One of the remaining issues microscopic thickness variation EG near surface steps, which induces variations in its electronic properties and device characteristics. We demonstrate here that layer are minimized by using microfabricated substrates spatially confines epitaxy. This technique will contribute realization highly reliable devices.
Heart failure with preserved ejection fraction (HFpEF), which is caused by wide various conditions, has become a major public health problem. Transthyretin amyloid cardiomyopathy (ATTR-CM), thought to be an underdiagnosed disease, can cause HFpEF. Non-invasive diagnosis using 99mTechnetium (Tc)-pyrophosphate (PYP) scintigraphy enables accurate of ATTR-CM. The aim this study was clarify the prevalence and characteristics ATTR-CM among Japanese patients This multicentre, prospective,...
To determine the effect of intravenous administration nicorandil on slow coronary flow (SCF) phenomenon in patients undergoing percutaneous intervention (PCI). In a preliminary study, 6 mg showed optimal efficacy for vasodilatation without causing significant haemodynamic instability. main total 408 were randomly assigned to receive immediately before PCI. The number group was 206 [acute syndrome (ACS): 47, non-ACS: 159] and that control 202 (ACS: 61, 141). Nicorandil significantly decreased...
This paper presents a capacitive silicon resonator with movable electrode structures to reduce the motional resistance for lower insertion loss and phase noise, also increase tuning frequency range compensation of temperature drift oscillator. The resonant fabricated device length 500 µm, width 440 µm thickness 5 is observed at 9.65 MHz, quality factor 49 000. Using an electrostatically drived structure, it shown that reduced by 200 times, output signal (insertion loss) increased 21 dB...
Abstract Sodium-glucose cotransporter 2 inhibitors could reduce cardiovascular events in patients with heart failure irrespective of diabetes status. In this prespecified sub-analysis randomised-controlled trial, we investigated the efficacy luseogliflozin (2.5 mg daily), a sodium–glucose inhibitor, that voglibose (0.6 an alpha-glucosidase on high-risk lipid profile and inflammatory markers type-2 failure. Among 157 studied, there were no significant differences mean malondialdehyde LDL or...
Background Most of the patients with pulmonary arterial hypertension (PAH) receiving intravenous epoprostenol have experienced catheter-related infections during long-term treatment. Catheter hub was reported to be most important source infections. To prevent infections, we introduced a closed system and compared incidence that in using non-closed system. Methods Results We evaluated results obtained on 24 occasions 20 PAH between June 1999 December 2005. On 11 occasions, used 13 cases...