M. Silarski

ORCID: 0000-0003-2206-0963
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Particle physics theoretical and experimental studies
  • Quantum Chromodynamics and Particle Interactions
  • Radiation Detection and Scintillator Technologies
  • Medical Imaging Techniques and Applications
  • High-Energy Particle Collisions Research
  • Atomic and Subatomic Physics Research
  • Nuclear Physics and Applications
  • Dark Matter and Cosmic Phenomena
  • Particle Detector Development and Performance
  • Muon and positron interactions and applications
  • Nuclear physics research studies
  • Radiation Therapy and Dosimetry
  • Advanced MRI Techniques and Applications
  • Noncommutative and Quantum Gravity Theories
  • Black Holes and Theoretical Physics
  • Ionosphere and magnetosphere dynamics
  • Advanced Radiotherapy Techniques
  • Advanced Semiconductor Detectors and Materials
  • Neutrino Physics Research
  • Boron Compounds in Chemistry
  • Advanced X-ray and CT Imaging
  • High-pressure geophysics and materials
  • Superconducting Materials and Applications
  • Cosmology and Gravitation Theories
  • Computational Physics and Python Applications

Jagiellonian University
2016-2025

Institute of Physics
2016-2025

Theranostics (New Zealand)
2024

Analog Devices (United States)
2024

Istituto Nazionale di Fisica Nucleare, Sezione di Milano
2021-2023

Politecnico di Milano
2021-2023

Consorzio di Bioingegneria e Informatica Medica
2023

Tohoku University
2023

Roma Tre University
2023

RIKEN
2021-2023

A detection system of the conventional PET tomograph is set-up to record data from e+ e- annihilation into two photons with energy 511 keV, and it gives information on density distribution a radiopharmaceutical in body object. In this paper we explore possibility performing three gamma imaging based ortho-positronium annihilation, as well positronium mean lifetime J-PET constructed plastic scintillators. For purposes simulations formation its were performed taking account distributions...

10.1088/1361-6560/aafe20 article EN cc-by Physics in Medicine and Biology 2019-01-14

The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET built from plastic scintillators.J-PET prototype consists of 192 detection modules arranged axially in three layers forming a cylindrical diagnostic chamber with inner diameter 85 cm and axial field-of-view 50 cm.An arrangement long strips scintillators, their small light attenuation, superior timing properties, relative ease increase opens promising perspectives for cost effective construction whole-body scanner, as well...

10.5506/aphyspolb.48.1567 article EN Acta Physica Polonica B 2017-01-01

Melanoma is an aggressive disease that arises from mutations in the cells produce pigment melanin, melanocytes. characterized by a high mortality rate, due to avoidance of applied therapies and metastasis other organs [1]. The peculiar features BNCT, particularly its cell-level selectivity Boron Neutron Capture Therapy (BNCT), make BNCT promising modality for melanoma treatment. However, appropriate cellular models should be used study new or improve efficacy existing therapies. Spheroids,...

10.20944/preprints202501.0141.v1 preprint EN 2025-01-03

The novel whole-body PET system based on plastic scintillators is developed by the {J-PET} Collaboration. It consists of scintillator strips arranged axially in form a cylinder, allowing cost-effective construction total-body PET. In order to determine properties scanner prototype and optimize its geometry, advanced computer simulations using GATE software were performed. spatial resolution, sensitivity, scatter fraction noise equivalent count rate estimated according NEMA norm as function...

10.1088/1361-6560/aad29b article EN cc-by Physics in Medicine and Biology 2018-07-11

The existence of a new force beyond the Standard Model is compelling because it could explain several striking astrophysical observations which fail standard interpretations. We searched for light vector mediator this dark force, $\mathrm{U}$ boson, with KLOE detector at DA$\Phi$NE $\mathrm{e}^{+}\mathrm{e}^{-}$ collider. Using an integrated luminosity 1.54 fb$^{-1}$, we studied process $\mathrm{e}^{+}\mathrm{e}^{-} \to \mathrm{U}\gamma$, $\mathrm{U} \mathrm{e}^{+}\mathrm{e}^{-}$, using...

10.1016/j.physletb.2015.10.003 article EN cc-by Physics Letters B 2015-10-17

We have searched for a light vector boson U, the possible carrier of "dark force", with KLOE detector at DAΦNE e+e− collider, motivated by astrophysical evidence presence dark matter in Universe. Using collisions collected an integrated luminosity 239.3 pb−1, we look dimuon mass peak reaction e+e−→μ+μ−γ, corresponding to decay U→μ+μ−. find no U signal. set 90% CL upper limit mixing parameter squared between photon and 1.6×10−5 8.6×10−7 region 520<mU<980 MeV.

10.1016/j.physletb.2014.08.005 article EN cc-by Physics Letters B 2014-08-07

The recent interest in a light gauge boson the framework of an extra U(1) symmetry motivates searches mass range below 1 GeV. We present search for such particle, dark photon, e+e−→Uγ, U→π+π− based on 28 million e+e−→π+π−γ events collected at DAΦNE by KLOE experiment. π+ π− production initial-state radiation compensates loss sensitivity previous U→e+e−, μ+μ− due to small branching ratios ρ–ω resonance region. found no evidence signal and set limit 90% CL mixing strength between photon ε2, U...

10.1016/j.physletb.2016.04.019 article EN cc-by Physics Letters B 2016-04-11

Charged lepton system symmetry under combined charge, parity, and time-reversal transformation (CPT) remains scarcely tested. Despite stringent quantum-electrodynamic limits, discrepancies in predictions for the electron-positron bound state (positronium atom) motivate further investigation, including fundamental tests. While CPT noninvariance effects could be manifested non-vanishing angular correlations between final-state photons spin of annihilating positronium, measurements were...

10.1038/s41467-021-25905-9 article EN cc-by Nature Communications 2021-09-27

Positronium is abundantly produced within the molecular voids of a patient’s body during positron emission tomography (PET). Its properties dynamically respond to submolecular architecture tissue and partial pressure oxygen. Current PET systems record only two annihilation photons cannot provide information about positronium lifetime. This study presents in vivo images lifetime human, for patient with glioblastoma brain tumor, by using dedicated Jagiellonian system enabling simultaneous...

10.1126/sciadv.adp2840 article EN cc-by-nc Science Advances 2024-09-13

Discrete symmetries play an important role in particle physics with violation of CP connected to the matter-antimatter imbalance Universe. We report most precise test P, T and invariance decays ortho-positronium, performed methodology involving polarization photons from these decays. Positronium, simplest bound state electron positron, is recent interest discrepancies reported between measured hyperfine energy structure theory at level $10^{-4}$ signaling a need for better understanding...

10.1038/s41467-023-44340-6 article EN cc-by Nature Communications 2024-01-02

Neutral kaon pairs produced in phi decays anti-symmetric entangled state can be exploited to search for violation of CPT symmetry and Lorentz invariance. We present an analysis the CP-violating process phi->K_S K_L->pi+pi-pi+pi- based on 1.7 fb-1 data collected by KLOE experiment at Frascati phi-factory DAFNE. The are used perform a measurement CPT-violating parameters Delta_amu neutral kaons contest Standard Model Extension framework. measured reference frame fixed stars are: Delta_ao =...

10.1016/j.physletb.2014.01.026 article EN cc-by Physics Letters B 2014-01-16

In this article it is presented an FPGA based $M$ulti-$V$oltage $T$hreshold (MVT) system which allows of sampling fast signals ($1-2$ ns rising and falling edge) in both voltage time domain. It possible to achieve a precision measurement $20$ ps RMS reconstruct charge signals, using simple approach, with deviation from real value smaller than 10$\%$. Utilization the differential inputs chip as comparators together implementation TDC inside allowed us compact multi-channel characterized by...

10.1088/1748-0221/12/08/p08001 article EN Journal of Instrumentation 2017-08-01

A novel approach to tomographic data processing has been developed and evaluated using the Jagiellonian PET (J-PET) scanner as an example. We propose a system in which there is no need for powerful, local facility, capable reconstruct images on fly. Instead we introduce Field Programmable Gate Array (FPGA) System-on-Chip (SoC) platform connected directly streams coming from scanner, can perform event building, filtering, coincidence search Region-Of-Response (ROR) reconstruction by...

10.1109/tmi.2018.2837741 article EN IEEE Transactions on Medical Imaging 2018-05-17

Recent tests of a single module the Jagiellonian Positron Emission Tomography system (J-PET) consisting 30 cm long plastic scintillator strips have proven its applicability for detection annihilation quanta (0.511 MeV) with coincidence resolving time (CRT) 0.266 ns. The achieved resolution is almost by factor two better respect to current TOF-PET detectors and it can still be improved since, as shown in this article, intrinsic limit determination interaction 0.511 MeV gamma scintillators...

10.1088/0031-9155/61/5/2025 article EN Physics in Medicine and Biology 2016-02-19

A bstract The three precision measurements of the cross section σ ( e + − → π γ(γ)) using initial state radiation by KLOE collaboration provide an important input for prediction hadronic contribution to anomalous magnetic moment muon. These are correlated both statistical and systematic uncertainties and, therefore, simultaneous use these requires covariance matrices that fully describe correlations. We present construction them determine a combined measurement γ(γ)). find, from this...

10.1007/jhep03(2018)173 article EN cc-by Journal of High Energy Physics 2018-03-01

We present a study of the application Jagiellonian positron emission tomograph (J-PET) for registration gamma quanta from decays ortho-positronium (o-Ps). The J-PET is first tomography scanner based on organic scintillators in contrast to all current PET scanners inorganic crystals. Monte Carlo simulations show that as an axially symmetric and high acceptance can be used multi-purpose detector well suited pursue research including e.g. tests discrete symmetries addition medical imaging....

10.1140/epjc/s10052-016-4294-3 article EN cc-by The European Physical Journal C 2016-08-01

We report the measurement of K− absorption processes in Σ0p final state and first exclusive two nucleon (2NA) with KLOE detector. The 2NA process without further interactions is found to be 9% sum all other contributing processes, including on three more nucleons or followed by residual nucleons. also determine possible contribution ppK− bound state. yield ppK−/Kstop− (0.044±0.009stat−0.005+0.004syst)⋅10−2 but its statistical significance based an F-test only 1σ.

10.1016/j.physletb.2016.05.001 article EN cc-by Physics Letters B 2016-05-04
Coming Soon ...