Tilo Niemann

ORCID: 0000-0002-5384-2522
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Radiation Dose and Imaging
  • Advanced X-ray and CT Imaging
  • Venous Thromboembolism Diagnosis and Management
  • Medical Imaging Techniques and Applications
  • Ultrasound in Clinical Applications
  • Advanced MRI Techniques and Applications
  • Medical Imaging and Pathology Studies
  • Cardiac tumors and thrombi
  • COVID-19 diagnosis using AI
  • Pediatric Urology and Nephrology Studies
  • Kidney Stones and Urolithiasis Treatments
  • Radiomics and Machine Learning in Medical Imaging
  • Lung Cancer Treatments and Mutations
  • Interstitial Lung Diseases and Idiopathic Pulmonary Fibrosis
  • Lung Cancer Diagnosis and Treatment
  • Bladder and Urothelial Cancer Treatments
  • Radiology practices and education
  • Advanced X-ray Imaging Techniques
  • Thyroid Cancer Diagnosis and Treatment
  • Nuclear Physics and Applications
  • Atomic and Subatomic Physics Research
  • Anatomy and Medical Technology
  • Abdominal Surgery and Complications
  • Cardiac Imaging and Diagnostics
  • Diagnosis and Treatment of Venous Diseases

Kantonsspital Baden
2016-2025

University of Zurich
2022-2025

University of Basel
2014-2020

University Hospital of Basel
2006-2014

Université de Lille
2014

Klinik und Poliklinik für Nuklearmedizin
2012-2014

Université Lille Nord de France
2013

Hospital Base
2009-2011

Post-mortem computed tomography (PMCT) has become a standard procedure in many forensic institutes worldwide. However, the scan protocols offered by vendors are optimised for clinical radiology and its main considerations regarding (CT), namely, radiation exposure motion artefacts. Thus, these aim at low-dose imaging fast techniques. negligible post-mortem imaging, which allows significantly increased image quality. Therefore, parameters have to be adjusted achieve best Several affect...

10.1177/0025802417747167 article EN Medicine Science and the Law 2018-01-01

Refraction-based x-ray imaging can overcome the fundamental contrast limit of computed tomography (CT), particularly in soft tissue, but so far has been constrained to high-dose ex vivo applications or required highly coherent sources, such as synchrotrons. Here we demonstrate that grating interferometry (GI) is more dose efficient than conventional CT human breast under close-to-clinical conditions. Our system, based on a source and commercial gratings, outperformed for spatial resolutions...

10.1364/optica.487795 article EN cc-by Optica 2023-06-23

Purpose To evaluate whether gadolinium penetrates human cerebrospinal fluid (CSF) after MR imaging (MRI) with a gadolinium-based contrast agent (GBCA). Materials and Methods For this retrospective study, the authors analyzed 60 CSF samples from 57 patients (median age, 50 years; range, 3-92 years) who underwent one material-enhanced MRI examination gadoterate meglumine within days of extraction between January December 2016. without material administration (n = 22) or those contrast-enhanced...

10.1148/radiol.2018171829 article EN Radiology 2018-05-08

Objective The aim of the study is to compare image quality and homogeneity vessel enhancement in high-pitch CT-angiography aorta (CTA) prior transcatheter aortic valve implantation between bolus tracking with a fixed trigger delay patient-specific delay. Materials Methods In this retrospective study, consecutive patients who received CTA January 2023 June 2024 were included. Patients imaged using either (Group A; 15 seconds) or B; FAST Bolus; Siemens Healthineers AG). same contrast injection...

10.1097/rli.0000000000001176 article EN cc-by Investigative Radiology 2025-03-20

The principal concern of any radiation exposure in computed tomography (CT) is the induction stochastic risks developing a radiation-induced cancer. results given this manuscript will allow to (re-)calculate yield chest CT.To demonstrate method evaluate lifetime attributable risk (LAR) cancer incidence/mortality due single diagnostic investigation 1-year cohort consecutive CT for suspected pulmonary embolism (PE).A PE using standard scan protocol was analyzed retrospectively (691 patients,...

10.1177/0284185113485069 article EN Acta Radiologica 2013-05-10

The discussion about setting up a program for lung cancer screening was launched with the publication of results National Lung Screening Trial, which suggested reduced mortality in high-risk subjects undergoing CT screening. However, important questions benefit-harm balance and details its cost-effectiveness remain unanswered. A panel specialists chest radiology, respiratory medicine, epidemiology, thoracic surgery representing all Swiss university hospitals prepared this joint statement...

10.1159/000357049 article EN Respiration 2014-01-01

The aim of this study was to compare a compressed-sensing free-breathing VIBE (fbVIBE) with conventional breath-hold (bhVIBE) for dynamic contrast-enhanced imaging the upper abdomen.In total, 70 datasets (bhVIBE, n = 30; fbVIBE 40; hard-gated [hg] reconstruction, motion-state-resolved [mr] 10) were assessed by 2 experienced readers. Both sequences performed on 1.5-T magnetic resonance scanners. prototypical sequence acquired navigation signal along data and supported different...

10.1097/rli.0000000000000607 article EN Investigative Radiology 2019-09-10

OBJECTIVE: To extract pulmonary and cardiovascular metrics from chest CTs of patients with coronavirus disease 2019 (COVID-19) using a fully automated deep learning-based approach assess their potential to predict patient management. MATERIALS AND METHODS: All initial who tested positive for severe acute respiratory syndrome 2 at our emergency department between March 25 April 25, 2020, were identified (n = 120). Three management groups defined: group 1 (outpatient), (general ward), 3...

10.3348/kjr.2020.0994 article EN Korean Journal of Radiology 2021-01-01

Background: Central venous catheters (CVCs) are indispensable tools in intensive care and emergency medicine. CVC malpositions still occur frequently can cause various complications leading to increased patient mortality. A microbubbles test (MBT) be used confirm correct positioning. However, there is serious doubt regarding whether the currently applied threshold of a 2 s push-to-bubbles time (PTB time) for rapid atrial swirl sign (RASS) an MBT reliable accurate. The aim present study was...

10.3390/jcm13061657 article EN Journal of Clinical Medicine 2024-03-14

Application of Cinematic Rendering in Clinical Routine CT Examination Ankle SprainsFlorian Berger1,2, Lars C. Ebert2, Rahel A. Kubik-Huch1, Karim Eid3, Michael J. Thali2 and Tilo Niemann1Audio Available | Share

10.2214/ajr.17.18630 article EN American Journal of Roentgenology 2018-09-07

Follow-up is essential for the early detection of recurrent non-muscle invasive bladder cancers (NMIBC). This study investigates clinical relevance new diagnostic tools such as an mRNA-based urine test (XPERT© Bladder Cancer Monitor, XBCM) and Narrow Band Imaging© (NBI) compares them with established follow-up diagnostics (white-light cystoscopy (WLC) cytology). was a prospective, double-blind, single-center that involved patients undergoing NMIBC screening at tertiary care center....

10.3390/cancers14030618 article EN Cancers 2022-01-26

Schistosomiasis is a helminthic infection that endemic in tropical and subtropical regions. Pulmonary involvement can be divided into two categories: acute or chronic compromise. Chronic recurrent develops persons living travelling areas. In the lungs, granuloma formation fibrosis around schistosome eggs retained pulmonary vasculature may result obliterative arteriolitis hypertension leading to cor pulmonale. Acute schistosomiasis associated with primary exposure commonly seen nonimmune...

10.3941/jrcr.v4i9.482 article EN cc-by-nc-nd Journal of Radiology Case Reports 2010-09-10

Presence of right ventricular thrombus (RVT) is a rare but life-threatening condition, thus immediate diagnosis and therapy are mandatory. Unfortunately, detection distinction from intraventricular tumour masses or vegetations represent complex task. Furthermore, consecutive principally led by clinical presentation without considering morphological features the thrombus. Current literature suggests multimodal non-invasive imaging approach. In this article, we discuss role cardiac magnetic...

10.1093/ehjcr/ytab340 article EN cc-by-nc European Heart Journal - Case Reports 2021-08-25

Abstract Objectives Different computed tomography (CT) scanners, variations in acquisition protocols, and technical parameters employed for image reconstruction may introduce bias the analysis of pericoronary adipose tissue (PCAT) attenuation derived from coronary angiography (CCTA). Therefore, aim this study was to establish effect tube voltage, measured as kilovoltage peak (kVp), iterative on PCAT mean (PCAT MA ). Methods Twelve healthy ex vivo porcine hearts were injected with...

10.1007/s00330-022-09274-5 article EN cc-by European Radiology 2022-12-06
Coming Soon ...