M. Tobin

ORCID: 0000-0002-2047-7020
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Particle physics theoretical and experimental studies
  • Quantum Chromodynamics and Particle Interactions
  • High-Energy Particle Collisions Research
  • Neutrino Physics Research
  • Particle Detector Development and Performance
  • Dark Matter and Cosmic Phenomena
  • Black Holes and Theoretical Physics
  • Computational Physics and Python Applications
  • Particle Accelerators and Free-Electron Lasers
  • Medical Imaging Techniques and Applications
  • Atomic and Subatomic Physics Research
  • Superconducting Materials and Applications
  • Radiation Detection and Scintillator Technologies
  • Nuclear physics research studies
  • Stochastic processes and statistical mechanics
  • Cosmology and Gravitation Theories
  • Distributed and Parallel Computing Systems
  • Advanced X-ray Imaging Techniques
  • International Science and Diplomacy
  • Astrophysics and Cosmic Phenomena
  • Advanced NMR Techniques and Applications
  • Digital Holography and Microscopy
  • Advanced Data Storage Technologies
  • Radiation Effects in Electronics
  • Markov Chains and Monte Carlo Methods

Institute of High Energy Physics
2019-2025

European Organization for Nuclear Research
2009-2025

Australian Nuclear Science and Technology Organisation
2019-2024

Australian Synchrotron
2014-2024

Chinese Academy of Sciences
2020-2024

Harvard University
2024

Beth Israel Deaconess Medical Center
2024

Tsinghua University
2020-2023

Laboratoire de Physique des 2 Infinis Irène Joliot-Curie
2021

Institut National de Physique Nucléaire et de Physique des Particules
2007-2021

The Vertex Locator (VELO) is a silicon microstrip detector that surrounds the proton-proton interaction region in LHCb experiment. performance of during first years its physics operation reviewed. system operated vacuum, uses bi-phase CO2 cooling system, and sensors are moved to 7 mm from LHC beam for data taking. stability these characteristic features described, details material budget given. calibration timing processing algorithms implemented FPGAs described. fully characterised. have...

10.1088/1748-0221/9/09/p09007 article EN cc-by Journal of Instrumentation 2014-09-09

In recent years, there has been a significant transformation in the field of incoherent imaging with new possibilities compressing three-dimensional (3D) information into two-dimensional intensity distribution without two-beam interference (TBI). Most 3D imagers TBI are based on scattering by random phase mask exhibiting sharp autocorrelation and low cross-correlation along depth. Consequently, during reconstruction, high lateral axial resolutions obtained. Imaging requires an astronomical...

10.29026/oes.2022.210006 article EN cc-by Opto-Electronic Science 2022-01-01

The soil carbon (C) saturation concept suggests an upper limit to the storage of organic (SOC). It is set by mechanisms that protect matter from mineralization. Biochar has capacity new C, including rhizodeposits and microbial necromass. However, decadal-scale which biochar influences molecular diversity, spatial heterogeneity, temporal changes in SOC persistence, remain unresolved. Here we show C ceiling a Ferralsol under subtropical pasture was raised second application Eucalyptus saligna...

10.1038/s41467-022-32819-7 article EN cc-by Nature Communications 2022-09-02

SALT, a new dedicated readout Application Specific Integrated Circuit (ASIC) for the Upstream Tracker, silicon detector in Large Hadron Collider beauty (LHCb) experiment, has been designed and developed. It is 128-channel chip using an innovative architecture comprising low-power analogue front-end with fast pulse shaping 40 MSps 6-bit Analog-to-Digital Converter (ADC) each channel, followed by Digital Signal Processing (DSP) block performing pedestal Mean Common Mode (MCM) subtraction zero...

10.3390/s22010107 article EN cc-by Sensors 2021-12-24

A focal plane array (FPA) detector was used for hyperspectral imaging in the infrared (IR) spectral region using thermal and synchrotron light sources. FPA Fourier-transform IR (FTIR) microspectroscopy will be able to monitor real time changes at specific absorption bands when combined with high brightness source. In this study, several types of samples unique structural motifs were selected assessing capability FPA-FTIR technique. It shown that required polariscopy wavelengths can...

10.20944/preprints201903.0127.v1 preprint EN 2019-03-11

Abstract The birefringence analysis of thin m SiO 2 films deposited via evaporation at a glancing angle to the normal on resist pillar arrays Si and nanopatterned substrates is carried out by spectral color (red–green–blue [RGB]) imaging modes. Retardance over flat structured regions can be distinguished with only ≈1% difference between neighboring for visible range using RGB numerical images. Michel‐Lévy map used rendering make quantitative measurements filtering. It shown that 530 nm...

10.1002/lpor.202200535 article EN publisher-specific-oa Laser & Photonics Review 2022-12-18

10.1016/j.nima.2015.10.100 article EN Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment 2015-11-20

Phase imaging of biochemical samples has been demonstrated for the first time at Infrared Microspectroscopy (IRM) beamline Australian Synchrotron using usually discarded Near-IR (NIR) region synchrotron-IR beam. The beam IRM a unique fork shaped intensity distribution as result gold coated extraction mirror shape, which includes central slit rejection intense X-ray resulting configuration makes any task challenging. For imaging, is tightly focused to point on sample plane followed by...

10.20944/preprints202210.0257.v1 preprint EN 2022-10-18

10.1016/j.nima.2016.05.115 article EN Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment 2016-06-12

The Beam Gas Vertex (BGV) detector is foreseen as a possible non-invasive beam size measurement instrument for the LHC and its luminosity upgrade. This technique based on reconstruction of beam-gas interaction vertices, where charged particles produced in inelastic interactions are measured with high-precision tracking detectors. design studies expected performance currently developed BGV prototype will be presented an overview given associated vacuum, readout systems. A brief description...

10.18429/jacow-ipac2014-thpme175 article EN 5th Int. Particle Accelerator Conf. (IPAC'14), Dresden, Germany, June 15-20, 2014 2014-06-16

10.1016/j.nima.2015.11.040 article EN Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment 2015-11-28

Corrosion of metallic surfaces is prevalent in the environment and great concern many areas, including military, transport, aviation, building food industries, amongst others. Polyester coatings containing both polyester silica nanoparticles (SiO2NPs) have been widely used to protect steel substrata from corrosion. In this study, we utilized X-ray photoelectron spectroscopy, attenuated total reflection infrared micro-spectroscopy, water contact angle measurements, optical profiling atomic...

10.3791/54309-v article EN Journal of Visualized Experiments 2016-10-11

Phase imaging of biochemical samples has been demonstrated for the first time at Infrared Microspectroscopy (IRM) beamline Australian Synchrotron using usually discarded near-IR (NIR) region synchrotron-IR beam. The beam IRM a unique fork shaped intensity distribution as result gold coated extraction mirror shape, which includes central slit rejection intense X-ray resulting configuration makes any task challenging. For imaging, is tightly focused to point on sample plane followed by...

10.3390/bios12121073 article EN cc-by Biosensors 2022-11-24

10.1016/j.nima.2024.169356 article EN Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment 2024-04-16
Coming Soon ...