Muhammad Abdul Rehman

ORCID: 0000-0002-6534-8409
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Particle accelerators and beam dynamics
  • Particle Accelerators and Free-Electron Lasers
  • Muon and positron interactions and applications
  • Particle physics theoretical and experimental studies
  • Particle Detector Development and Performance
  • Plasma Diagnostics and Applications
  • Superconducting Materials and Applications
  • Gyrotron and Vacuum Electronics Research
  • High-Energy Particle Collisions Research
  • Atomic and Molecular Physics
  • Energy Harvesting in Wireless Networks
  • Quantum Chromodynamics and Particle Interactions
  • Radiation Detection and Scintillator Technologies
  • Electrostatic Discharge in Electronics
  • Neutrino Physics Research
  • Real-time simulation and control systems
  • Advanced Radiotherapy Techniques
  • Pulsed Power Technology Applications
  • Multimodal Machine Learning Applications
  • Heat Transfer Mechanisms
  • Drilling and Well Engineering
  • Topic Modeling
  • Granular flow and fluidized beds
  • Hydraulic Fracturing and Reservoir Analysis
  • Geotechnical and Geomechanical Engineering

National University of Sciences and Technology
2023-2024

High Energy Accelerator Research Organization
2021-2024

Institute of High Energy Physics
2024

Chinese Academy of Sciences
2024

China Spallation Neutron Source
2024

Air University
2023

Mari Petroleum Company (Pakistan)
2023

University of Bergen
2023

University of Koblenz and Landau
2023

University of Kaiserslautern
2023

This paper introduces a new approach to measure the muon magnetic moment anomaly |$a_{\mu} = (g-2)/2$| and electric dipole (EDM) |$d_{\mu}$| at J-PARC facility. The goal of our experiment is |$a_{\mu}$| using an independent method with factor 10 lower momentum, 20 smaller diameter storage-ring solenoid compared previous ongoing |$g-2$| experiments unprecedented quality storage field. Additional significant differences from present experimental include 1000 transverse emittance beam...

10.1093/ptep/ptz030 article EN cc-by Progress of Theoretical and Experimental Physics 2019-03-18

The movement of biological fluids in the human body is a premium field interest to overcome growing biomedical challenges. Blood behavior shows different capillaries, veins, and arteries during circulation. In this paper, new mathematical relation for nano-layer flows with effect TiO2 Ag hybrid nanoparticles was developed. Further, we explain engineering phenomena role blood vessel system. improvement drug delivery systems by using low seepage Reynolds number associated expansion/contraction...

10.3390/axioms12020163 article EN cc-by Axioms 2023-02-06

Abstract The Associated Proton beam Experiment Platform (APEP) beamline is the first proton irradiation facility to use naturally-stripped protons which come from H-beams interacting with residual gas in linac beampipe at CSNS. stripped current, order of 0.1% original H-beam and approximately 10 μA, should be measured precisely provide number for experiments. Therefore, a low-intensity current measurement system was developed considerations eliminate external interferences. An...

10.1088/1742-6596/2681/1/012001 article EN Journal of Physics Conference Series 2024-01-01

Abstract The emission of muonium ($\mu^+e^-$) atoms into vacuum from silica aerogel with laser ablation on its surface was studied various structures at room temperature using the subsurface muon beams TRIUMF and Japan Proton Accelerator Research Complex (J-PARC). Laser applied to produce holes or grooves typical dimensions a few hundred $\mu$m mm, except for some extreme conditions. measured rate tends be higher larger fractions opening shallower depths. More than reach rates similar...

10.1093/ptep/ptaa145 article EN cc-by Progress of Theoretical and Experimental Physics 2020-09-17

This paper introduces a new approach to measure the muon magnetic moment anomaly $a_{\mu} = (g-2)/2$, and electric dipole (EDM) $d_{\mu}$ at J-PARC facility. The goal of our experiment is $a_{\mu}$ using an independent method with factor 10 lower momentum, 20 smaller diameter storage-ring solenoid compared previous ongoing $g-2$ experiments unprecedented quality storage field. Additional significant differences from present experimental include 1,000 transverse emittance beam (reaccelerated...

10.48550/arxiv.1901.03047 preprint EN other-oa arXiv (Cornell University) 2019-01-01

Abstract The direct simultaneous detection of electron and positron bunch signals was successfully performed for the first time with wideband pickups a system at capture section SuperKEKB factory. interval between bunches, their lengths, intensities depending on phase accelerating structures were measured to investigate process maximally optimize intensity. results show that intervals in range 135–265 ps, line-order switch bunches axial direction clearly observed as function phase....

10.1038/s41598-021-91707-0 article EN cc-by Scientific Reports 2021-06-17

The development of a vertical kicker system is an important part three-dimensional spiral-injection scheme. beam injected at pitch angle few tens degrees was controlled by applying pulsed magnetic field using inside the storage magnet. stored muon then followed betatron motion around midplane magnet owing to weak focusing field. Accurate control kick crucial for minimizing amplitude oscillation. specifications and detailed design test bench are discussed herein.

10.1109/tasc.2022.3164996 article EN IEEE Transactions on Applied Superconductivity 2022-04-05

Neutral uncharged molecules are affected by the electromagnetic field of a charged particle beam if they carry either an electric or magnetic dipole moment. The residual gas in accelerator pipe consists such molecules. In this paper we study their dynamics. Under few approximations, whose validity explore and justify, derive equations motion neutral invariants, determine conditions for these to become trapped beams as function beam-pipe temperature, compute resulting enhancement molecule...

10.1103/physrevaccelbeams.24.054001 article EN cc-by Physical Review Accelerators and Beams 2021-05-12

Abstract In the J-PARC Muon g -2/EDM experiment, to measure muon anomalous magnetic moment ( -2) and electrical dipole (EDM), it is necessary accumulate 300MeV/ c beams with a 66 cm diameter region 3 T solenoid-type field. A new three-dimensional spiral injection scheme has been invented achieve this target. Since first instance employ scheme, scale-down experiment an electron beam of 297 keV/ storage 24 established at KEK. simplified monitor using scintillating fiber designed fabricated...

10.1088/1742-6596/2687/2/022035 article EN Journal of Physics Conference Series 2024-01-01

We present the performance of a full-length prototype ALICE Forward Calorimeter (FoCal). The detector is composed silicon-tungsten electromagnetic sampling calorimeter with longitudinal and transverse segmentation (FoCal-E) about 20$X_0$ hadronic copper-scintillating-fiber (FoCal-H) 5$λ_{\rm int}$. data were taken between 2021 2023 at CERN PS SPS beam lines hadron (electron) beams up to energies 350 (300) GeV. Regarding FoCal-E, we report comprehensive analysis its response minimum ionizing...

10.48550/arxiv.2311.07413 preprint EN cc-by arXiv (Cornell University) 2023-01-01

10.1016/j.nima.2021.165703 article EN Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment 2021-08-04

10.18429/jacow-ibic2021-mopp10 article EN 10th International Beam Instrumentation Conference (IBIC'21), Pohang, Rep. of Korea, 24-28 May 2021 2021-10-01

We conducted a test experiment on three-dimensional (3-D) spiral beam injection to be performed in Japan Proton Accelerator Research Complex (J-PARC) muon g-2/EDM experiment. For successful 3-D injection, the horizontal and vertical correlations (X-Y coupling) phase space of beams must properly controlled. X-Y coupling is controlled by k-values rotation angles quadrupole magnets. This paper reports manufacture mechanism attached rotatable-quadrupole magnets The allows for mechanical remote...

10.1109/tasc.2022.3162810 article EN IEEE Transactions on Applied Superconductivity 2022-03-28

KEK electron positron injector LINAC initiated the injection operation into Photon Factory (PF) light source in 1982. Since then for 39 years, it has served multiple projects, namely, TRISTAN, PF-AR, KEKB, and SuperKEKB. Its total time accumulated 200 thousand hours on May 7, 2020. We are extremely proud of achievement following continuous efforts by our seniors. The construction started 1978, was commissioned PF with 2.5 GeV In parallel, generator linac constructed TRISTAN collider project....

10.1088/1742-6596/2420/1/012021 article EN Journal of Physics Conference Series 2023-01-01

Abstract Drilling through narrow drilling margins in wildcat wells always proves to be a challenging task where uncertainties regarding windows make operators decide bottom hole equivalent circulating densities (ECDs) based on unclear data, resulting loss/gain scenario during drilling. This paper describes the effective use of constant pressure (CBHP) variant Managed Pressure (MPD) well X-1 explain successful reservoir section, providing an incredibly window 0.08 SG across Lockhart &...

10.2118/217012-ms article EN 2023-10-02

10.18429/jacow-linac2018-thpo017 article EN 29\textsuperscript{th} Linear Accelerator Conf. (LINAC'18), Beijing, China, 16-21 September 2018 2019-01-01

Abstract A new experiment at J-PARC (E34) is under construction to measure the muon's g – 2 unprecedented precision of 0.1 ppm and electric dipole moment up sensitivity 10 –21 e.cm in order explore physics beyond standard model. novel three-dimensional spiral injection scheme has been devised inject store beam into a small diameter MRI-type storage magnet for E34. The features smooth with high efficiency compact magnet. However, an unproven idea, therefore, Spiral Injection Test Experiment...

10.1088/1742-6596/1350/1/012151 article EN Journal of Physics Conference Series 2019-11-01
Coming Soon ...