P. Kvasnička

ORCID: 0000-0001-6281-0648
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Particle physics theoretical and experimental studies
  • Particle Detector Development and Performance
  • Radiation Detection and Scintillator Technologies
  • Quantum Chromodynamics and Particle Interactions
  • High-Energy Particle Collisions Research
  • Particle Accelerators and Free-Electron Lasers
  • CCD and CMOS Imaging Sensors
  • Computational Physics and Python Applications
  • Dark Matter and Cosmic Phenomena
  • Medical Imaging Techniques and Applications
  • Spectroscopy and Quantum Chemical Studies
  • Superconducting Materials and Applications
  • Lipid Membrane Structure and Behavior
  • Black Holes and Theoretical Physics
  • Radiation Effects in Electronics
  • Adipose Tissue and Metabolism
  • Atomic and Subatomic Physics Research
  • Advanced Glycation End Products research
  • Ion Transport and Channel Regulation
  • Eicosanoids and Hypertension Pharmacology
  • Electron and X-Ray Spectroscopy Techniques
  • Protein Interaction Studies and Fluorescence Analysis
  • Neonatal Health and Biochemistry
  • Astrophysics and Cosmic Phenomena
  • Adipokines, Inflammation, and Metabolic Diseases

Charles University
2014-2023

Halbleiterlabor of the Max-Planck-Society
2023

Instituto de Física de Cantabria
2023

Universitat de Barcelona
2023

Johannes Gutenberg University Mainz
2023

Ludwig-Maximilians-Universität München
2023

Technical University of Munich
2023

Max Planck Institute for Physics
2023

University of Bonn
2018-2022

Indian Institute of Technology Madras
2016-2020

Abstract The Silicon Vertex Detector of Belle II is a state-of-the-art tracking and vertexing system based on double-sided silicon strip sensors, designed fabricated by large international collaboration in the period 2012–2018. Since 2019 it has been operation providing high quality data with small number defective channels (<1%), hit-finding efficiency (>99%), good signal-to-noise ratio (well excess 10 for all sensor configurations tracks). Together control over alignment, these are...

10.1088/1748-0221/17/11/p11042 article EN Journal of Instrumentation 2022-11-01

The DEPFET collaboration develops highly granular, ultra-transparent active pixel detectors for high-performance vertex reconstruction at future collider experiments. characterization of detector prototypes has proven that the key principle, integration a first amplification stage in detector-grade sensor material, can provide comfortable signal to noise ratio over 40 thickness 50-75 $\mathrm{\mathbf{\mu m}}$. ASICs have been designed and produced operate with required read-out speed. A...

10.1109/tns.2013.2245680 article EN IEEE Transactions on Nuclear Science 2013-03-21

<para xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> For the detection of secondary vertices long lived particles containing bottom and charm quarks at International Linear Collider (ILC), a DEPFET pixel detector is one technologically favored options. In sensor MOSFET integrated on sidewards depleted silicon bulk sensor, thus combining advantages fully with in-pixel amplification. matrices have been characterized in high energy particle beam....

10.1109/tns.2007.914031 article EN IEEE Transactions on Nuclear Science 2008-01-01

The objective of this study was to investigate the response Na(+)/K(+)-ATPase human erythrocytes green laser irradiation. Effects light fluences 9.5-63.3 J.cm(-2) and merocyanine 540-mediated treatment were studied. Isolated erythrocyte membranes (protein concentration 1 mg/ml) irradiated by Nd:YAG (532 nm, 30 mW) then incubated in a medium with 2 mM ATP for min. Activity ATPase determined colorimetrically measuring colored reaction product liberated inorganic phosphate malachite at 640 nm....

10.33549/physiolres.930711 article EN cc-by-nc Physiological Research 2006-01-01

We report a search for B0 decays into invisible final states using data sample of 657×106 B¯¯¯B pairs collected at the Υ(4S) resonance with Belle detector KEKB e+e− collider. The signal is identified by fully reconstructing hadronic decay accompanying B meson and requiring no other particles in event. No significant observed, we obtain an upper limit 1.3×10−4 90% confidence level branching fraction decay.Received 26 June 2012DOI:https://doi.org/10.1103/PhysRevD.86.032002© 2012 American...

10.1103/physrevd.86.032002 article EN publisher-specific-oa Physical review. D. Particles, fields, gravitation, and cosmology/Physical review. D, Particles, fields, gravitation, and cosmology 2012-08-01

The brain stem contains important nuclei that control cardiovascular function via the sympathetic nervous system (SNS), which is strongly influenced by nitric oxide. Its biological activity also largely determined oxygen free radicals. Despite many experimental studies, role of AT1R-NAD(P)H oxidase-superoxide pathway in NO-deficiency not yet sufficiently clarified. We changes radical signaling and antioxidant detoxification response young adult Wistar rats during chronic administration...

10.1186/s12929-017-0366-4 article EN cc-by Journal of Biomedical Science 2017-09-11

A new synthetic isothiocyanate (ITC) derivative, ethyl 4-isothiocyanatobutanoate (E-4IB), appeared to be an effective modulator of cellular proliferation and potent inducer apoptosis. In cooperation with cisplatin, this compound exerted synergistic effects in human ovarian carcinoma A2780 cells. the present study we investigated more detail E4IB-sensitisation for cisplatin-induced Sequential administration both cytostatic agents led increased intracellular platinum accumulation, glutathione...

10.1038/sj.bjc.6603434 article EN cc-by-nc-sa British Journal of Cancer 2006-10-24

10.1016/j.nima.2009.01.097 article EN Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment 2009-02-05

The future Belle II experiment will employ a computer-farm based data reduction system for the readout of its innermost detector, DEPFET-technology silicon detector with pixel readout. A large fraction background hits can be rejected by defining set Regions Of Interest (ROI) on sensors and then recording just from pixels inside ROI. ROIs are defined an event basis extrapolating back onto PXD charged tracks detected in outer trackers (a 4 layer double-sided strip surrounded wire chamber)....

10.1109/tns.2015.2419879 article EN IEEE Transactions on Nuclear Science 2015-05-06

We present a computer-farm based data reduction system for the pixel detector of future Belle II experiment. is major upgrade that currently ongoing in KEK (Tsukuba, Japan). will collect from SuperKEKB, an asymmetric e <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">+</sup> xmlns:xlink="http://www.w3.org/1999/xlink">-</sup> collider whose target luminosity (8 × 10 xmlns:xlink="http://www.w3.org/1999/xlink">35</sup> Hz/cm...

10.1109/rtc.2014.7097438 article EN 2014-05-01

We report on a search for the charmless decays B+→ϕπ+ and B0→ϕπ0 that are strongly suppressed in standard model. The analysis is based data sample of 657×106 B¯¯¯B pairs collected at Υ(4S) resonance with Belle detector KEKB asymmetric-energy e+e− collider. find no significant signal set upper limits 3.3×10−7 1.5×10−7 90% confidence level.Received 20 June 2012DOI:https://doi.org/10.1103/PhysRevD.86.031101© 2012 American Physical Society

10.1103/physrevd.86.031101 article EN publisher-specific-oa Physical review. D. Particles, fields, gravitation, and cosmology/Physical review. D, Particles, fields, gravitation, and cosmology 2012-08-07

The Belle II Silicon Vertex Detector comprises four layers of double-sided silicon strip detectors (DSSDs), consisting ladders with two to five sensors each. All are individually read out by APV25 chips the Origami chip-on-sensor concept for central DSSDs ladders. sit on flexible circuits that glued top sensors. This allows a low material budget and an efficient cooling single pipe per ladder. We present construction first SVD results from precision measurements electrical tests.

10.1088/1748-0221/11/01/c01087 article EN Journal of Instrumentation 2016-01-29

The fluorescence lifetime distribution of 1,6‐diphenyl‐1,3,5‐hexatriene (DPH) and 1‐[4‐(trimethylamino)phenyll‐6‐phenyl‐1,3,5‐hexatriene (TMA‐DPH) in egg‐phosphatidylcholine liposomes was measured normal heavy water. lower dielectric constant (by ∼12%) water compared with employed to provide direct evidence that the drop along membrane shifts centers both DPH TMA‐DPH higher values sharpens widths distribution. profile not found be a linear gradient (in contrast [1]) but more complex...

10.1016/0014-5793(95)01138-5 article EN FEBS Letters 1995-11-06

10.1016/j.nima.2010.06.170 article EN Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment 2010-07-04
Coming Soon ...