C. Lacasta

ORCID: 0000-0002-2623-6252
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Particle physics theoretical and experimental studies
  • High-Energy Particle Collisions Research
  • Particle Detector Development and Performance
  • Quantum Chromodynamics and Particle Interactions
  • Dark Matter and Cosmic Phenomena
  • Radiation Detection and Scintillator Technologies
  • Computational Physics and Python Applications
  • Cosmology and Gravitation Theories
  • Neutrino Physics Research
  • Medical Imaging Techniques and Applications
  • Nuclear Physics and Applications
  • Radiation Therapy and Dosimetry
  • CCD and CMOS Imaging Sensors
  • Black Holes and Theoretical Physics
  • Astrophysics and Cosmic Phenomena
  • Distributed and Parallel Computing Systems
  • Particle Accelerators and Free-Electron Lasers
  • Radiation Effects in Electronics
  • Atomic and Subatomic Physics Research
  • Plant and soil sciences
  • Advanced X-ray and CT Imaging
  • Advanced Radiotherapy Techniques
  • Crop Yield and Soil Fertility
  • Muon and positron interactions and applications
  • Superconducting Materials and Applications

Instituto de Física Corpuscular
2016-2025

Universitat de València
2016-2025

AGH University of Krakow
2013-2024

Jagiellonian University
2017-2024

A. Alikhanyan National Laboratory
2024

SR Research (Canada)
2024

Federación Española de Enfermedades Raras
2024

University of Toronto
2024

Atlas Scientific (United States)
2024

The University of Adelaide
2014-2023

The Belle detector at the KEKB electron-positron collider has collected almost 1 billion Y(4S) events in its decade of operation. Super-KEKB, an upgrade is under construction, to increase luminosity by two orders magnitude during a three-year shutdown, with ultimate goal 8E35 /cm^2 /s luminosity. To exploit increased luminosity, been proposed. A new international collaboration Belle-II, being formed. Technical Design Report presents physics motivation, basic methods accelerator upgrade, as...

10.48550/arxiv.1011.0352 preprint EN other-oa arXiv (Cornell University) 2010-01-01

Abstract The ATLAS experiment is constructing new all-silicon inner tracking system for HL-LHC. strip detectors cover the radial extent of 40 to 100 cm. A approach adopted use p-type silicon material, making readout in n + -strips, so-called -in-p sensors. This allows enhanced radiation tolerance against an order magnitude higher particle fluence compared LHC. To cope with varying hit rates and occupancies as a function distance, there are two barrel sensor types, short strips (SS) 2 long...

10.1088/1748-0221/18/03/t03008 article EN Journal of Instrumentation 2023-03-01

Compton Cameras emerged as an alternative for real-time dose monitoring techniques Particle Therapy (PT), based on the detection of prompt-gammas. As a consequence scattering process, gamma origin point can be restricted onto surface cone (Compton cone). Through image reconstruction techniques, distribution emitters estimated, using cone-surfaces backprojections cones through space, along with more sophisticated statistical methods to improve quality. To calculate required reconstruction,...

10.1088/0031-9155/60/5/1845 article EN Physics in Medicine and Biology 2015-02-06

Compton imaging devices have been proposed and studied for a wide range of applications. We developed camera prototype which can be operated with two or three detector layers based on monolithic lanthanum bromide ([Formula: see text]) crystals coupled to silicon photomultipliers (SiPMs), used proton verification in hadron therapy. In this work, we present the results obtained our laboratory tests radioactive sources simulation studies. Images [Formula: text]Na an text]Y successfully...

10.1088/1361-6560/aa8070 article EN Physics in Medicine and Biology 2017-07-18

In order to exploit the advantages of ion-beam therapy in a clinical setting, delivery verification techniques are necessary detect deviations from planned treatment. Efforts currently oriented towards development devices for real-time range monitoring. Among different detector concepts proposed, Compton cameras employed prompt gammas and represent valid candidate verification. We present first on-beam test MACACO, telescope (multi-layer camera) based on lanthanum bromide crystals silicon...

10.1088/0031-9155/61/14/5149 article EN Physics in Medicine and Biology 2016-06-28

Abstract Targeting a peak luminosity of 6 × 10 35 cm -2 s -1 , the Belle II experiment at SuperKEKB in Japan is considering an upgrade its interaction region. This involves vertex detector, which will be replaced by new fully pixelated detector (VTX). A monolithic CMOS pixel sensor named OBELIX (Optimized BELle pIXel) proposed to used VTX. Based on existing TJ-Monopix2 chip initially developed for ATLAS Inner Tracker (ITk) upgrade, designed 180 nm process with improved matrix and additional...

10.1088/1748-0221/20/02/c02046 article EN Journal of Instrumentation 2025-02-01

Abstract The ATLAS experiment at the Large Hadron Collider (LHC) is currently preparing to replace its present Inner Detector (ID) with upgraded, all-silicon Tracker (ITk) for High-Luminosity upgrade (HL-LHC). ITk will consist of a central pixel tracker and outer strip tracker, consisting about 19,000 detector modules. Each module assembled from up two sensors, five flexes (depending on geometry) in series gluing, wirebonding quality control steps. During operation, modules be cooled down...

10.1088/1748-0221/20/03/p03004 article EN cc-by Journal of Instrumentation 2025-03-01

The characterization of a PET detector head based on continuous LYSO crystals and silicon photomultiplier (SiPM) arrays as photodetectors has been carried out for its use in the development small animal prototype. heads are composed crystal SiPM matrix with 64 pixels common substrate, fabricated specifically this project. Three 12 mm × 5 size different types painting have tested: white, black sides but white back crystal. best energy resolution, obtained crystal, is 16% FWHM. response linear...

10.1088/0031-9155/55/23/008 article EN Physics in Medicine and Biology 2010-11-16

10.1016/j.nima.2012.08.074 article EN Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment 2012-08-31

10.1016/j.nima.2014.06.086 article EN publisher-specific-oa Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment 2014-07-14

A Compton telescope for dose monitoring in hadron therapy is under development at IFIC. The system consists of three layers LaBr3 crystals coupled to silicon photomultiplier arrays. Na-22 sources have been successfully imaged reconstructing the data with an ML-EM code. Calibration and temperature stabilization are necessary prototype operation low coincidence rates. spatial resolution 7.8 mm FWHM has obtained first imaging tests.

10.3389/fonc.2016.00014 article EN cc-by Frontiers in Oncology 2016-02-02

The production of strip sensors for the ATLAS Inner Tracker (ITk) started in 2021. Since then, a Quality Assurance (QA) program has been carried out continuously, by using specific test structures, parallel to Control (QC) inspection sensors. QA consists monitoring sensor-specific characteristics and technological process variability, before after irradiation with gammas, neutrons, protons. After two years, half full volume reached we present an analysis parameters measured as part process....

10.1016/j.nima.2024.169435 article EN cc-by-nc-nd Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment 2024-05-14

The DEPFET collaboration develops highly granular, ultra-transparent active pixel detectors for high-performance vertex reconstruction at future collider experiments. characterization of detector prototypes has proven that the key principle, integration a first amplification stage in detector-grade sensor material, can provide comfortable signal to noise ratio over 40 thickness 50-75 $\mathrm{\mathbf{\mu m}}$. ASICs have been designed and produced operate with required read-out speed. A...

10.1109/tns.2013.2245680 article EN IEEE Transactions on Nuclear Science 2013-03-21

10.1016/j.nima.2011.11.041 article EN Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment 2011-12-02

Given the strong variations in sensitivity of Compton cameras for detection events originating from different points field view (FoV), correction is often necessary image reconstruction. Several approaches calculation matrix have been proposed literature. While most these models are easily implemented and can be useful many cases, they usually assume high angular coverage over scattered photon, which not case our prototype. In this work, we derived an analytical model that allows us to...

10.1088/1361-6560/aac8cd article EN Physics in Medicine and Biology 2018-05-30

10.1016/j.nima.2012.08.094 article EN Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment 2012-09-05

10.1016/j.nima.2016.04.035 article EN publisher-specific-oa Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment 2016-04-13

The ATLAS experiment will replace its existing Inner Detector with the new all-silicon Tracker (ITk) to cope operating conditions of forthcoming high-luminosity phase LHC (HL-LHC). outer regions ITk be instrumented ∼18000 ATLAS18 strip sensors fabricated by Hamamatsu Photonics K.K. (HPK). With launch full-scale sensor production in 2021, community has undertaken quality control (QC) testing these ensure compliance mechanical and electrical specifications agreed HPK. is conducted at seven QC...

10.1016/j.nima.2024.169457 article EN cc-by Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment 2024-05-21

Electronically collimated gamma cameras based on Compton scattering in silicon pad sensors may improve imaging nuclear medicine and biomedical research. The work described concentrates the detector for a prototype camera. are read out using low noise very large scale integration (VLSI) CMOS chips novel fast triggering chips. Depending application, lightweight dense packaging of its readout electronics hybrid is required. We describe sensor their newly designed hybrid. also present modular...

10.1109/tns.2002.1039568 article EN IEEE Transactions on Nuclear Science 2002-06-01
Coming Soon ...